Dimensions
Height - 5.3" / 135 mm
Width - 6.9" / 170 mm
Depth - 16.4" / 418 mm
Weight - 13.2 lb/ 6 kg
Power Requirement
100–240 V, 50/60 Hz
110 VA
Performance Specs
λ Range - 190 - 840 nm
Spectral Half-width - 10 nm
Adj. Accuracy - ± 1 nm
Reproducibility - ± 0.5 nm
Noise - ± 5 x 10-5 AU
Drift - 1 x 10-3 AU/h
 
Follow Semba Biosciences on Twitter Follow us on Twitter

Your Cart My Cart
• My Account
• Privacy Policy
• Terms & Conditions
• Help


BBB accreditation

© Semba Biosciences, Inc.
505 South Rosa Road
Suite 106A
Madison WI 53719
Tel.  608 441 8009
Toll Free  
866 634 1114
Fax 
608 441 8329

Bookmark and Share

The Octave 4X UV/VIS Detector

DescriptionOctave 4X UV/VIS Detector

The Octave 4X UV/VIS Detector is engineered for seamless integration with Semba’s Octave Chromatography System. This versatile instrument provides simultaneous detection at up to four different wavelengths ranging from 190 nm to 840 nm in a single channel. The diode array design enables reliable, reproducible performance and minimal noise levels. Dual deuterium and halogen light sources provide sensitive detection over the wide range of wavelengths, and a built-in counter monitors work hours for both lamps.

The detector is controlled by the SembaView™ software application, which can display the output of two Octave 4X UV/VIS Detectors for simultaneous monitoring of two outlet streams (e.g. Extract and Raffinate). Several flow cells are available ranging in application from analytical (up to 50 ml/min, 5 mm path length) to preparative (up to 500 ml/min, 0.3 or 2.4 mm path length). The cell is easy to replace from the side of the detector.

Technical Specifications

[]
  Wavelength range 190–840 nm
  Typical spectral half-width 10 nm
  Accuracy of adjustment ± 1 nm
  Reproducibility ± 0.5 nm
  Light source Deuterium discharge lamp
and halogen lamp
  Noise level at test cell (254 nm, TC 0.75 s) ± 5 x 10-5 AU
  Drift at test cell (254 nm after 1 h) 1 x 10-3 AU/h
  Materials in contact with mobile phase PTFE; fused silica, PEEK or stainless steel
  Time constant (T90) 0.5 s; 0.75 s; 1 s or 2 s
(T63 0.3s; 0.4s; 0.6s; 1s)
  Output for integrator 1 V/AU
  Interface RS232
  Power supply 100–240 V 50/60 Hz 110VA
  Dimensions (W x H x D) 5.3" x 6.7" x 16.4" (135 x 170 x 418 mm)
  Weight 13.2 lb (6.0 kg)


Analytical and Preparative Flow Cells

[]
   
 

Preparative Flow Cell

Analytical Flow Cell

 

Volume/optical path

45 μl/0.3 mm or 70 μl/2.4 mm

10 μl/5 mm

 

Cell connection

tubing with OD = 1/8",
¼ 28 flat bottom

tubing with OD = 1/16",
10-32 coned

 

Maximal flow rate

500 ml/min

50 ml/min

 

Material

PEEK or Stainless Steel

PEEK

Ordering Information

Octave™ 4X UV/VIS Detector - Includes one flow cell H1016K
Add to Cart
Prep Flow Cell 0.3, PEEKH1021E
Add to Cart
Prep Flow Cell 0.3, Stainless Steel  H1023E
Add to Cart
Prep Flow Cell 2.4, PEEK H1017E
Add to Cart
Prep Flow Cell 2.4, Stainless Steel   H1024E
Add to Cart
Analytical Flow Cell, PEEK H1022E
Add to Cart

Product Literature

Octave™ 4X UV/VIS Detector Brochure